Site
Web
Home
Products
News
About
Contact Us
You are here:
Products
|
Login
Search
Categories
All Products
Clinical Microdialysis
Clinical Microdialysis Accessories
Clinical Microdialysis Analysers
Clinical Microdialysis Catheters
Microdialysis Catheters Clinical Research
Microdialysis Catheters Neuro Monitoring
Microdialysis Catheters Reconstructive Surgery
Environmental Monitoring / Respirometery
Fluid Handling
Multiwell High Throughput Dispenser
Peristaltic Pumps
Syringe Pumps
Accessories, Servicing and Spare Parts:
Continuous Flow Syringe Pumps
Dual Rate Syringe Pumps
EZFLOW – Economical Syringe Pumps
High Pressure Syringe Pumps
Infusion Syringe Pumps
Infusion Withdrawal Syringe Pumps
Interactive Pump Systems
Legato Syringe Pumps
OEM Syringe Pumps
OrchesTA Infusion System
Pico Litre Syringe Pumps
Programmable Syringe Pumps
Push/Pull Syringe Pumps
Speciality Products
Syringe Pump Recommendations by Application
Aerosol Spray:
Assay Development:
Bulk Fluid Injections:
Cell Cultures:
Cell Injection:
Chemical Reactor Injection:
Coatings:
Compound Storage:
Drug Delivery:
Drug/Nutrition Infusion:
Electrospinning:
ELSIA:
Fluid Sampling:
Gradients:
High Pressure Injections:
HPLC:
Low Volume Dispensing:
Mass Spectrometer Calibration:
Microdialysis:
Microfluidics/Nanofluidics:
Multiple (5-10) Injections / Infusions
Neuroscience:
Nutritional Studies:
Perfusion Chamber:
Primary/Secondary Screening:
Syringes
Gas Mixing / Blending
Human Physiology
fNIR Functional Near Infrared Brain Imaging
fNIR Sensors
fNIR Systems
fNIR Analysis Software
Actigraphy
BIOPAC
BIOPAC Accessories
BIOPAC Electrodes
BIOPAC Software
BIOPAC Transducers
Multuple Camera Systems
Research
BIOPAC Amplifiers and Modules
Bioimpedance
BioNomadix
BioNomadix Accessories
BioNomadix Electrode Leads
BioNomadix Transducers
BioNomadix Wireless Amplifiers
Biopotentials
Gas Analysis
Interface Modules
Laser Doppler Flow
Microelectrode
NIBP - Non-Invasive Blood Pressure
Temperature
Transducer Amplifiers
Systems
B-Alert Wireless EEG
BioNomadix Logger
BIOPAC MP100
BIOPAC MP160
BIOPAC MP36R
Teaching
Biopac Science Laboratory
Higher Education
Dynamometers
Pinch Strength Gauge
Sensory Evaluation
Stimulus Presentation
Telemetry and Remote Physiological Monitoring
Vibromyography
Virtual Reality
in vitro
Electrophysiology
Freezing Stages for Microtomes
Heating and Cooling Stages for Microscopes
Microinjection
Micromanipulators
Micropipette Fabrication
Optical & Imaging Products
Microscopes
Stimulators
Tissue / Sample Preparation
Tissue baths, Transducers, Stimulators
in vivo
Blood Pressure, Vital Functions
Blood Sampling
Blood/Liquid Flow Monitoring
Calorimetry / Respiratory Gas Analysis
Cardiac Output (Thermodilution)
CLAMS - Comprehensive Laboratory Animal Monitoring
CNS, Nociceptive, Behaviour
Analgesia / Nociceptive / Inflammation
Conditioning, Reward
Locomotor Activity, Mazes and Tracking
Exercise
Feeding Tubes
Food and Drink Consumption Monitoring
Heating and Cooling Stages for Microscopes
Infusion
Catheters
Implantable Infusion Pumps
Infusion Accessories
Infusion Kits
Ports
Swivel Mounts
Swivels
Tethers
Tubing
Microspheres
Motory Coordination, Grip Strength, Activity
Pressure and PV Catheters
Pressure Tipped Catheters
Pressure Volume (PV) Systems
Sensory Evaluation
Telemetry
E-Mitter Mouse telemetry Products
Epoch animal telemetry products
Temperature Monitoring
Ugo Basile Accessories
Ventilators and Gas Anaesthesia
Microdialysis
MRI
Enquiry List
Your Enquiry List is empty
Products
m-Dialysis 61 Hepatic Microdialysis Catheter
For Microdialysis monitoring in hepatic tissue Introduced during open surgery Easy to insert into the tissue with a splitable introducer Fixation to the liver by attached suture
Code
61 Hepatic Microdial
Add to Enquiry List
Description
Documentation
m-Dialysis 61 Hepatic Microdialysis Catheter
For Microdialysis monitoring in hepatic tissue
Introduced during open surgery
Easy to insert into the tissue with a splitable introducer
Fixation to the liver by attached suture
The sterile, single use 61 Hepatic Microdialysis Catheter allows continuous monitoring of the hepatic tissue metabolism. The dialysing membrane of the 61 Hepatic Microdialysis Catheter is designed to achieve excellent diffusion characteristics, allowing a high recovery of substances from the extra cellular fluid.
The 61 Catheter has a shaft length of 310 mm and a 30 mm membrane. During open surgery the catheter is introduced into the abdominal cavity by using the tunnelating needle. Insertion into the liver is achieved with the help of a splitable introducer. After insertion into the transplanted liver the catheter is sutured to the falciform ligament. The catheter can be implanted for several days.
The catheter inlet tubing is connected to a Microdialysis Pump and the outlet ends in a microvial which collects the sample. The samples can be analyzed in the Microdilaysis Analyzer for Glucose, Lactate, Pyruvate, Glycerol, Glutamate and Urea or sent to the laboratory for further analysis.
Technical information 61 Catheter
Membrane Cut-off: Approx. 20,000 Daltons
Material
Length (mm)
Diameter (mm)
Inner Shaft
Polyurethane
310
0.9
Outer shaft
Polyurethane
280
1.5
Membrane
PAES *
30
0.6
Inlet Tubing
Polyurethane
400
1.0
Outlet Tubing
Polyurethane
70
1.0
* PAES = Polyarylethersulphone
Ordering information for 61 Catheter
Ref. No.
8010226 61 Hepatic Microdialysis Catheter 4/pkg incl. Splitable Introducer SI-2 4/pkg
Accessories:
P000001 Microvials
P000028 Microvials in Rack
P000154 Microvials in Rack Sterile
P000055 Tunnelating needle
Product Documentation
61 Hepatic Microdialysis Catheter Brochure
Download
Previous
Storefront
Enquire about this product
Privacy Statement
|
Terms Of Use
Copyright 2011 by Linton Instrumentation