Site
Web
Home
Products
News
About
Contact Us
You are here:
Products
|
Login
Search
Categories
All Products
Clinical Microdialysis
Clinical Microdialysis Accessories
Clinical Microdialysis Analysers
Clinical Microdialysis Catheters
Microdialysis Catheters Clinical Research
Microdialysis Catheters Neuro Monitoring
Microdialysis Catheters Reconstructive Surgery
Environmental Monitoring / Respirometery
Fluid Handling
Multiwell High Throughput Dispenser
Peristaltic Pumps
Syringe Pumps
Accessories, Servicing and Spare Parts:
Continuous Flow Syringe Pumps
Dual Rate Syringe Pumps
EZFLOW – Economical Syringe Pumps
High Pressure Syringe Pumps
Infusion Syringe Pumps
Infusion Withdrawal Syringe Pumps
Interactive Pump Systems
Legato Syringe Pumps
OEM Syringe Pumps
OrchesTA Infusion System
Pico Litre Syringe Pumps
Programmable Syringe Pumps
Push/Pull Syringe Pumps
Speciality Products
Syringe Pump Recommendations by Application
Aerosol Spray:
Assay Development:
Bulk Fluid Injections:
Cell Cultures:
Cell Injection:
Chemical Reactor Injection:
Coatings:
Compound Storage:
Drug Delivery:
Drug/Nutrition Infusion:
Electrospinning:
ELSIA:
Fluid Sampling:
Gradients:
High Pressure Injections:
HPLC:
Low Volume Dispensing:
Mass Spectrometer Calibration:
Microdialysis:
Microfluidics/Nanofluidics:
Multiple (5-10) Injections / Infusions
Neuroscience:
Nutritional Studies:
Perfusion Chamber:
Primary/Secondary Screening:
Syringes
Gas Mixing / Blending
Human Physiology
fNIR Functional Near Infrared Brain Imaging
fNIR Sensors
fNIR Systems
fNIR Analysis Software
Actigraphy
BIOPAC
BIOPAC Accessories
BIOPAC Electrodes
BIOPAC Software
BIOPAC Transducers
Multuple Camera Systems
Research
BIOPAC Amplifiers and Modules
Bioimpedance
BioNomadix
BioNomadix Accessories
BioNomadix Electrode Leads
BioNomadix Transducers
BioNomadix Wireless Amplifiers
Biopotentials
Gas Analysis
Interface Modules
Laser Doppler Flow
Microelectrode
NIBP - Non-Invasive Blood Pressure
Temperature
Transducer Amplifiers
Systems
B-Alert Wireless EEG
BioNomadix Logger
BIOPAC MP100
BIOPAC MP160
BIOPAC MP36R
Teaching
Biopac Science Laboratory
Higher Education
Dynamometers
Pinch Strength Gauge
Sensory Evaluation
Stimulus Presentation
Telemetry and Remote Physiological Monitoring
Vibromyography
Virtual Reality
in vitro
Electrophysiology
Freezing Stages for Microtomes
Heating and Cooling Stages for Microscopes
Microinjection
Micromanipulators
Micropipette Fabrication
Optical & Imaging Products
Microscopes
Stimulators
Tissue / Sample Preparation
Tissue baths, Transducers, Stimulators
in vivo
Blood Pressure, Vital Functions
Blood Sampling
Blood/Liquid Flow Monitoring
Calorimetry / Respiratory Gas Analysis
Cardiac Output (Thermodilution)
CLAMS - Comprehensive Laboratory Animal Monitoring
CNS, Nociceptive, Behaviour
Analgesia / Nociceptive / Inflammation
Conditioning, Reward
Locomotor Activity, Mazes and Tracking
Exercise
Feeding Tubes
Food and Drink Consumption Monitoring
Heating and Cooling Stages for Microscopes
Infusion
Catheters
Implantable Infusion Pumps
Infusion Accessories
Infusion Kits
Ports
Swivel Mounts
Swivels
Tethers
Tubing
Microspheres
Motory Coordination, Grip Strength, Activity
Pressure and PV Catheters
Pressure Tipped Catheters
Pressure Volume (PV) Systems
Sensory Evaluation
Telemetry
E-Mitter Mouse telemetry Products
Epoch animal telemetry products
Temperature Monitoring
Ugo Basile Accessories
Ventilators and Gas Anaesthesia
Microdialysis
MRI
Enquiry List
Your Enquiry List is empty
Products
m-Dialysis 70 Brain Microdialysis Catheter with Gold tip
For early detection of brain ischemia and vasospasm Minimally invasive Can be implanted for several days
Code
70 Brain Microdialys
Add to Enquiry List
Description
Documentation
m-Dialysis 70 Brain Microdialysis Catheter with Gold tip
For early detection of brain ischemia and vasospasm
Minimally invasive
Can be implanted for several days
The sterile single use 70 Microdialysis Catheter is a highly flexible catheter designed for implantation in brain tissue. A selection of 70 Microdialysis Catheters is available with different membrane and shaft lengths suitable for stereotaxical as well as manual implantation.
The 70 Microdialysis Catheter is tunnelated under the scalp with a tunnelating needle. It is then inserted with the help of microdialysis forceps into the brain tissue through a hole drilled in the skull bone.
The tip of the Catheter contains a gold thread, which makes it visible on a CT-scan in order to locate the exact position of the catheter in the brain.
The catheter inlet tubing is connected to a Microdialysis Pump and the outlet ends in a microvial which collects the sample. The samples can be analyzed in the Microdialysis Analyzer for Glucose, Lactate, Pyruvate, Glycerol, Glutamate and Urea or sent to the laboratory for further analysis.
Technical information for 70 Brain Catheter
Membrane Cut-off: Approx. 20,000 Daltons
hghghgjgjhgjhgjhgjhgjhg
Material
Length (mm)
Diameter (mm)
Shaft
Polyurethane
0.9
Membrane
Polyamide
0.6
Inlet Tubing
Polyurethane
600
1.0
Outlet Tubing
Polyurethane
220
1.0
Ordering information for 70 Brain Catheter
Ref. No.
P000049 membrane length 10 mm -shaft 60 mm 4/pkg
P000080 membrane length 20 mm -shaft 60 mm 4/pkg **
P000081 membrane length 30 mm -shaft 60 mm 4/pkg **
P000050 membrane length 10 mm -shaft 100 mm 4/pkg **
P000051 membrane length 20 mm -shaft 90 mm 4/pkg **
P000052 membrane length 30 mm -shaft 80 mm 4/pkg **
** Non stock items and produced by order (8-10 weeks delivery time)
P000050-P000052 are made for stereotaxic use
Accessories:
P000001 Microvials
P000028 Microvial Rack
P000154 Microvials in Rack Sterile
Product Documentation
70 Brain Microdialysis Catheter with Gold Tip Brochure
Download
Previous
Storefront
Enquire about this product
Privacy Statement
|
Terms Of Use
Copyright 2011 by Linton Instrumentation