Site
Web
Home
Products
News
About
Contact Us
You are here:
Products
|
Login
Search
Categories
All Products
Environmental Monitoring / Respirometery
Fluid Handling
Multiwell High Throughput Dispenser
Spill Sensing
Syringe Pumps
Accessories, Servicing and Spare Parts:
Continuous Flow Syringe Pumps
Dual Rate Syringe Pumps
EZFLOW – Economical Syringe Pumps
High Pressure Syringe Pumps
Infusion Syringe Pumps
Infusion Withdrawal Syringe Pumps
Interactive Pump Systems
Legato Syringe Pumps
OEM Syringe Pumps
Pico Litre Syringe Pumps
Programmable Syringe Pumps
Push/Pull Syringe Pumps
Speciality Products
Syringe Pump Recommendations by Application
Aerosol Spray:
Assay Development:
Bulk Fluid Injections:
Cell Cultures:
Cell Injection:
Chemical Reactor Injection:
Coatings:
Compound Storage:
Drug Delivery:
Drug/Nutrition Infusion:
Electrospinning:
ELSIA:
Fluid Sampling:
Gradients:
High Pressure Injections:
HPLC:
Low Volume Dispensing:
Mass Spectrometer Calibration:
Microdialysis:
Microfluidics/Nanofluidics:
Multiple (5-10) Injections / Infusions
Neuroscience:
Nutritional Studies:
Perfusion Chamber:
Primary/Secondary Screening:
Syringes
Gas Mixing / Blending
Human Physiology
fNIR Functional Near Infrared Brain Imaging
Actigraphy
Biopac
Biopac Electrodes
Biopac Transducers
Research
Biopac Amplifiers and Modules
Bioimpedance
BioNomadix
BioNomadix Accessories
BioNomadix Electrode Leads
BioNomadix Transducers
BioNomadix Transmitter-Receiver Pairs
Biopotentials
Gas Analysis
Interface Modules
Laser Doppler Flow
Microelectrode
NIBP - Non-Invasive Blood Pressure
Temperature
Transducer Amplifiers
Systems
B-Alert Wireless EEG
Biopac MP100
Biopac MP150
Biopac MP36R
Teaching
Biopac Science Laboratory
Higher Education
Stimulus Presentation
Telemetry and Remote Physiological Monitoring
Vibromyography
Virtual Reality
in vitro
Freezing Stages for Microtomes
Heating and Cooling Stages for Microscopes
Microinjection
Micromanipulators
Micropipette Fabrication
Optical & Imaging Products
Microscopes
Stimulators
Tissue / Sample Preparation
Tissue baths, Transducers, Stimulators
in vivo
Blood Pressure, Vital Functions
Blood Sampling
Blood/Liquid Flow Monitoring
Calorimetry / Respiratory Gas Analysis
Cardiac Output (Thermodilution)
CLAMS - Comprehensive Laboratory Animal Monitoring
CNS, Nociceptive, Behaviour
Analgesia / Nociceptive / Inflammation
Conditioning, Reward
Locomotor Activity, Mazes and Tracking
Exercise
Feeding Tubes
Food and Drink Consumption Monitoring
Heating and Cooling Stages for Microscopes
Infusion
Catheters
Implantable Infusion Pumps
Infusion Accessories
Infusion Kits
Ports
Swivel Mounts
Swivels
Tethers
Tubing
Microspheres
Motory Coordination, Grip Strength, Activity
Pressure and PV Catheters
Pressure Tipped Catheters
Pressure Volume (PV) Systems
Temperature Monitoring
Ugo Basile Accessories
Ventilators and Gas Anaesthesia
Microdialysis
MRI
Enquiry List
Your Enquiry List is empty
Products
Biopac NIBP250 Stand Alone NIBP System
The NIBP250 small animal tail noninvasive blood pressure monitor is a stand-alone device to measure the blood pressure of small animals and has a touch screen LCD user interface to control the system and display the data.
Code
NIBP250
Add to Enquiry List
Description
Biopac NIBP250 Stand Alone NIBP System
The NIBP250 small animal tail noninvasive blood pressure monitor is a
stand-alone
device to measure the blood pressure of small animals and has a touch screen LCD user interface to control the system and display the data. The monitor does not require a data acquisition system or computer to analyze the data, but can interface with existing BIOPAC data acquisition platforms and third-party systems when combining other physiological signals.
The NIBP250 is completely stand-alone; displaying, analyzing and saving the data for further use.
The NIBP250 incorporates a built-in pump that automatically inflates the blood pressure cuff to occlude the vessel in the tail of a rat or similar small animal. Once the pump reaches the inflation point it slowly deflates the cuff, providing a linear drop in pressure.
A touchscreen LCD monitors the pressure and pulse signals. Use the simple touchscreen interface (or connect a USB mouse if preferred) to easily mark the points where systolic and diastolic blood pressure appear. The system uses a peak detection routine that locates the peak of each of the pressure pulses and marks it with an asterisk. The cursors jumps from peak to peak and provides instantaneous readings for systolic and diastolic blood pressure. The NIBP250 displays the marked values for the systolic and the diastolic blood pressures and the calculated values for the mean blood pressure and the heart rate in the results window. The values are also displayed adjacent to the cursors.
The maximum inflation point can be adjusted in the properties window. The NIBP250 also includes pressure calibration and validation tools to be able to refresh and check the factory calibration. The cuff assembly attaches to the equipment via a Luer lock connector and the pulse sensor attaches via a BNC connector. The equipment also has a gain adjustment control to amplify or attenuate the pulse signal. NIBP250 provides two analog outputs for uncalibrated pressure and pulse waveforms.
The NIBP250 module has a USB 1.1 compatible flash memory port and SD card slot to move data to a computer for further analysis and publishing. It reports the raw and analyzed data files in ascii format which can easily be imported into your favorite application (e.g. AcqKnowledge, Excel, SPSS, MATLAB, etc.).
Each NIBP250 system includes:
1 - amplifier unit (switching power supply works for 110 V or 220 V)
1 - cuff/sensor (size 11 mm is included, but can be specified as 9.5 mm or 13 mm when ordering)
1 - restrainer (size medium is included, but can be specified as small or large when ordering)
1 - Pulse cable to MP System or third-party A/D hardware
1 - Pressure cable to MP System or third-party A/D hardware
Setup and calibration details are in the Hardware Guide.
Optional accessories
Tail Heating Unit TAILHEATING-A (110 V 60 Hz) or TAILHEATING-B (220 V 50 Hz)
Specifications
Cut-off Pressure Range: 100 – 300 mmHg (adjustable by 1mmHg steps)
Pressure Accuracy: 300 mmHg Full Scale 1%
Pressure Sensitivity: 0.1 mmHg
Pressure Signal output: 300 mmHg/3 Volt DC
Pulse Gain Levels: x1, x2, x4, x5, x8, x16, x32 (adjustable)
Pulse Signal Output: 0- 4 Volt DC
Pulse Display: Pulse intensity is displayed on A2, derived from plethysmographic measures. The tail sensor detects blood flow and pulse intensity is increased or decreased, depending on the flow ratio.
LCD Display: 7” 800x480 TFT
User Interface: Resistive Touch Panel
Analog outputs: Two BNC connectors for uncalibrated pressure and pulse signals
Triggers: Two BNC connectors for TTL Compatible trigger in and out signals
USB port:1.1 compatible (use for flash memory or computer nmouse)
Card Slot: SD card slot
Power Supply: 12 Volt 2 Amp – External
NIBP250 Quick Guide
Prepare
- While the unit is turned OFF, attach the sensor and cuff connectors.
- Turn the unit ON and wait for the unit to start and show the main acquisition screen.
- Prepare the animal and attach the sensor-cuff to its tail.
Acquire
- When the animal is prepped, press the Start button on the main screen to start the acquisition of the cuff pressure and the blood pulsations. The button label changes to Stop and you can stop the acquisition in any emergency situation.
- When the acquisition starts, the unit automatically closes the leakage valve and starts the pump for inflating the cuff.
- After the pressure reaches the maximum level it stops the pump and opens the leakage valve to make the pressure decrease slowly. The acquisition stops when the pressure reduced to the certain level.
Analyze
- After the acquisition stops, the unit automatically finds the peaks of pulsations using the pre-configured parameters, and a marker guide will appear on the screen.
- The marker can be moved along the time axis by your finger or by the cursor buttons on the top-right. You can change the movement mode by checking the peak-by-peak option under the buttons.
- After moving the marker to the systolic or the diastolic peaks, press the Sys or Dia buttons to calculate the corresponding pressure values. After marking the diastolic peak, the unit will automatically calculate the heart rate and and show it in the results section.
- Peak positions can be changed any time during analyzing step.
- Press the Save button under the results--this will automatically generate a result code that will be displayed on the top of the results section.
Save Results
- The previously saved results can be listed by pressing the Load button in the results section. Then a list will appear showing the analyzed results and the date of saving for each measurement with the result code.
- By marking the desired measurement and pressing OK button you can load the recorded pressure and pulse curves and the previously calculated results.
- After loading finishes, you can easily evaluate the results and re-analyze your measurement.
Turn Off
- Before turning off the unit, be sure that the last measurement was saved.
- Power off the unit by switching the power button on the back.
Previous
Storefront
Enquire about this product
Privacy Statement
|
Terms Of Use
Copyright 2011 by Linton Instrumentation