Pressure Catheters
fp891b
fp895b
pr-mouse-tip-sm

Scisense Single and Dual Sensor Pressure Tipped Catheters

Single and Dual Sensor Pressure Tipped Catheters (compatible with Scisense or Millar control units.
Code
Pressure Catheters

Scisense Single and Dual Sensor Pressure Tipped Catheters

Scisense Single and Dual Sensor Pressure-Tipper Catheters



Single Pressure Catheters




Class: Small Animal / Rodent



Model # Name Description
FTS-1211B-0018 1.2F Pressure Catheter The ideal catheter for measuring arterial or ventricular pressure in the mouse.
FTS-1611B-0018 1.6F Pressure Catheter The ideal catheter for measuring arterial and cardiac pressures in the rat as well as pressures within small vessels for larger animals such as rabbits.



Class: Medium Animal / Rabbit



Model # Name Description
FTS-3511B-0024 3.5F Pressure Catheter A 3.5F pressure catheter ideal for measuring arterial and ventricular pressures in the rabbit. Ideal for invasive large animal studies where an apical approach is preferred.



Class: Large Animals (dog, pig, sheep)




Model # Name Description
FTS-5011B-0048B 5.0F Pressure Catheter with a Pigtail Tip A 5.0F pressure catheter with closed-pigtail designed specifically for closed chest protocols where a carotid artery insertion will be used.
FTS-5011B-0048D 5.0F Pressure Catheter with a Straight Tip A 5.0F pressure catheter ideal for vessel pressures or LV pressure studies where an open chest surgery and apical insertion is used.



Class: Larger Animals (dog, pig, sheep)




Model # Name Description
FTS-7011B-0048A 7.0F Pressure Catheter with a Pigtail Tip and Lumen A 7.0F pressure catheter with guidewire or injection lumen designed specifically for closed chest protocols where a carotid or femoral artery insertion will be used. The central lumen can be used for administering compounds or blood sampling.
FTS-7011B-0048B 7.0F Pressure Catheter with a Closed Pigtail Tip A 7.0F pressure catheter with closed-pigtail designed specifically for closed chest protocols where a carotid artery insertion will be used.
FTS-7011B-0048C 7.0F Pressure Catheter with a Straight Tip and Lumen A 7.0F pressure catheter ideal for vessel pressures or LV pressure studies where an open chest surgery and apical insertion is used. A central catheter lumen is accessible for drug administration and blood sampling.
FTS-7011B-0048D 7.0F Pressure Catheter with a Straight Tip A 7.0F pressure catheter ideal for vessel pressures or LV pressure studies where an open chest surgery and apical insertion is used.






Dual Pressure Catheters




Class: Small Animal / Rodent



Model # Name Description
FTS-1215B-0018-1 1.2F Dual Pressure Catheter A specialty 1.2F catheter with two pressure sensors: the first sensor is located at the tip of the catheter, while the second is located 1 cm more proximal. This catheter is typically used to measure simultaneous left ventricular pressure and carotid blood pressure in the mouse. The distance between the two sensors can be customized without any additional cost.
FTS-1215B-0018-2 1.2F Dual Pressure Catheter A specialty 1.2F catheter with two pressure sensors: the first sensor is located at the tip of the catheter, while the second is located 2 cm more proximal. This catheter is typically used to measure simultaneous left ventricular pressure and carotid blood pressure in the mouse. The distance between the two sensors can be customized without any additional cost.
FTS-1215B-0018-5 1.2F Dual Pressure Catheter A specialty 1.2F catheter with two pressure sensors: the first sensor is located at the tip of the catheter, while the second is located 5 cm more proximal. This catheter is typically used to measure simultaneous left ventricular pressure and carotid blood pressure in the mouse. The distance between the two sensors can be customized without any additional cost.
FTS-1615B-0018-2 1.6F Dual Pressure Catheter A specialty 1.6F catheter with two pressure sensors: the first sensor is located at the tip of the catheter, while the second is located 2 cm more proximal. This catheter is typically used to measure simultaneous left ventricular pressure and carotid blood pressure in the rat. The distance between the two sensors can be customized without any additional cost.
FTS-1615B-0018-4 1.6F Dual Pressure Catheter A specialty 1.6F catheter with two pressure sensors: the first sensor is located at the tip of the catheter, while the second is located 4 cm more proximal. This catheter is typically used to measure simultaneous left ventricular pressure and carotid blood pressure in the rat. The distance between the two sensors can be customized without any additional cost.
FTS-1615B-0018-7 1.6F Dual Pressure Catheter A specialty 1.6F catheter with two pressure sensors: the first sensor is located at the tip of the catheter, while the second is located 7 cm more proximal. This catheter is typically used to measure simultaneous left ventricular pressure and carotid blood pressure in the rat. The distance between the two sensors can be customized without any additional cost.



Class: Medium Animal / Rabbit
Model # Name Description
FTS-3515B-0024-3 3.5F Dual Pressure Catheter A specialty 3.5F catheter with two pressure sensors: the first sensor is located at the tip of the catheter, while the second is located 3 cm more proximal. This catheter is typically used to measure simultaneous left ventricular pressure and carotid blood pressure in the rabbit. The distance between the two sensors can be customized without any additional cost.
FTS-3515B-0024-4 3.5F Dual Pressure Catheter A specialty 3.5F catheter with two pressure sensors: the first sensor is located at the tip of the catheter, while the second is located 4 cm more proximal. This catheter is typically used to measure simultaneous left ventricular pressure and carotid blood pressure in the rabbit. The distance between the two sensors can be customized without any additional cost.



Class: Large Animals (dog, pig, sheep)




Model # Name Description
FTS-5015B-0048B-5 5.0F Dual Pressure Catheter with a Pigtail Tip A specialty 5.0F catheter with two pressure sensors to be used in carotid or femoral artery insertions into the ventricle: the first sensor is located slightly proximal of the tip, while the second is proximal by 5 cm. Note that the distance between the two sensors can be adjusted as required at no extra cost.
FTS-5015B-0048D-5 5.0F Dual Pressure Catheter with a Straight Tip A specialty 5.0F catheter with two pressure sensors to be used for vessel pressures or chamber pressures where an open chest surgery and apical insertion is used. The first sensor is located slightly proximal of the tip, while the second is proximal by 5 cm. Note that the distance between the two sensors can be adjusted as required at no extra cost.
FTS-7015B-0048A-5 7.0F Dual Pressure Catheter with a Pigtail Tip and Lumen A specialty 7.0F catheter with two pressure sensors to be used in carotid or femoral artery insertions into the ventricle: the first sensor is located slightly proximal of the tip, while the second is proximal by 5 cm. Note that the distance between the two sensors can be adjusted as required at no extra cost. A central catheter lumen is accessible for drug administration, blood sampling, or guidewire insertion
FTS-7015B-0048B-5 7.0F Dual Pressure Catheter with a Closed Pigtail Tip A specialty 7.0F catheter with two pressure sensors to be used in carotid or femoral artery insertions into the ventricle: the first sensor is located slightly proximal of the tip, while the second is proximal by 5 cm. Note that the distance between the two sensors can be adjusted as required at no extra cost.
FTS-7015B-0048C-5 7.0F Dual Pressure Catheter with a Straight Tip and Lumen A specialty 7.0F catheter with two pressure sensors to be used for vessel pressures or chamber pressures where an open chest surgery and apical insertion is used. The first sensor is located slightly proximal of the tip, while the second is proximal by 5 cm. Note that the distance between the two sensors can be adjusted as required at no extra cost. A central catheter lumen is accessible for drug administration and blood sampling
FTS-7015B-0048D-5 7.0F Dual Pressure Catheter with a Straight Tip A specialty 7.0F catheter with two pressure sensors to be used for vessel pressures or chamber pressures where an open chest surgery and apical insertion is used. The first sensor is located slightly proximal of the tip, while the second is proximal by 5 cm. Note that the distance between the two sensors can be adjusted as required at no extra cost.